Your browser doesn't support javascript.
Шоу: 20 | 50 | 100
Результаты 1 - 5 de 5
Фильтр
Добавить фильтры

база данных
Годовой диапазон
1.
J Infect Dis ; 226(8): 1396-1400, 2022 10 17.
Статья в английский | MEDLINE | ID: covidwho-2077785

Реферат

After >2 years of the coronavirus disease 2019 (COVID-19) pandemic, immunoglobulins (IGs) contain highly potent severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) neutralizing antibodies, based on the large proportion of United States (US) plasma donors who have gone through COVID-19 or vaccination against the virus. Neutralization of Omicron SARS-CoV-2 by antibodies generated after non-Omicron infection or vaccination has been lower though, raising concerns about the potency of IG against this new virus variant. Also, as plasma collected in the US remains the main source of IG, the neutralization of SARS-CoV-2 for plasma collected elsewhere has been less well studied. Here, we confirm Omicron neutralization by US as well as European Union plasma-derived IG lots.


Тема - темы
Antibodies, Neutralizing , COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing/immunology , Antibodies, Viral , COVID-19/immunology , Europe , Humans , Neutralization Tests , Spike Glycoprotein, Coronavirus , United States
2.
Frontiers in medicine ; 9, 2022.
Статья в английский | EuropePMC | ID: covidwho-1989529

Реферат

Background During the current pandemic, the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) neutralization capacity of the immunoglobulin (IG) supply has changed from undetectable for lots manufactured from plasma collected before the pandemic, to now highly potent. Objective As antibodies induced by exposure to or vaccination against coronaviruses were shown to be cross-coronavirus reactive, it was of interest to understand whether SARS-CoV-2 neutralizing antibodies would result in increased functional IG potency also against seasonal coronaviruses. Methods IG lots from US plasma collected before SARS-CoV-2 emerged and collected during the pandemic were analyzed by live virus neutralization assay for SARS-CoV-2 and seasonal human coronaviruses (HCoVs) NL63 and OC43 neutralizing antibody content. Results Pre-pandemic IG showed no SARS-CoV-2 neutralizing antibody titers. However, IG lots produced from plasma of post-coronavirus disease 2019 (COVID-19) individuals exhibited robust anti-SARS-CoV-2 potency (1,267 IU/ml) which further increased ~4-fold in pandemic IG lots reaching a mean titer of 5,122 IU/ml. Nonetheless, neutralizing antibody potencies to the HCoVs NL63 and OC43 remained stable over this period, i.e., have not increased correspondingly. Conclusion The present results show that cross-coronavirus-reactive antibodies are not cross-neutralizing, i.e., SARS-CoV-2 antibodies do not neutralize seasonal coronaviruses NL63 and OC43.

3.
J Infect Dis ; 226(8): 1357-1361, 2022 10 17.
Статья в английский | MEDLINE | ID: covidwho-1706826

Реферат

Immunoglobulin lots (N = 176) released since March 2020 were tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) neutralizing antibodies, with first positive results for September 2020 lots (mean, 1.7 IU/mL; 46% of lots positive). From there, values steadily increased, in correlation with the cumulative coronavirus disease 2019 (COVID-19) incidence, to reach a mean of 31.2 IU/mL and 93% of lots positive by January 2021. Extrapolating the correlation, immunoglobulins could reach an anti-SARS-CoV-2 potency of approximately 345 IU/mL by July 2021. At that stage, prophylactic immunoglobulin treatment for primary/secondary immunodeficiency could contain similar doses of anti-SARS-CoV-2 as convalescent plasma that is used for treatment of COVID-19.


Тема - темы
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/therapy , Humans , Immunization, Passive/methods , Immunoglobulins, Intravenous/therapeutic use , Pandemics/prevention & control , COVID-19 Serotherapy
4.
J Infect Dis ; 224(10): 1707-1711, 2021 11 22.
Статья в английский | MEDLINE | ID: covidwho-1541544

Реферат

From September 2020, some immunoglobulin lots from US plasma contained neutralizing antibodies against the newly emerged severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Paralleled by the increasing numbers of post-coronavirus disease 2019 (COVID-19) donors, immunoglobulin lot antibody positivity increased to 93% by January 2021, at a mean titer of approximately 30 IU/mL. The correlation predicted that anti-SARS-CoV-2 potency would reach 345 IU/mL by July 2021. In addition to post-COVID-19 donors, the rapidly increasing number of plasma donors vaccinated against COVID-19 resulted in a mean antibody titer of >600 IU/mL in July 2021 immunoglobulin lots, with SARS-CoV-2 antibody titers for several lots even higher than those of earlier produced hyperimmune globulin products.


Тема - темы
COVID-19 , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/therapy , Humans , Immunization, Passive , Immunoglobulins, Intravenous/therapeutic use , COVID-19 Serotherapy
5.
J Infect Dis ; 222(12): 1960-1964, 2020 Nov 13.
Статья в английский | MEDLINE | ID: covidwho-780405

Реферат

The 2020 SARS-CoV-2 pandemic is caused by a zoonotic coronavirus transmitted to humans, similar to earlier events. Whether the other, seasonally circulating coronaviruses induce cross-reactive, potentially even cross-neutralizing, antibodies to the new species in humans is unclear. The question is particularly relevant for people with immune deficiencies, as their health depends on treatment with immunoglobulin preparations that need to contain neutralizing antibodies against the pathogens in their environment. Testing 54 intravenous immunoglobulin preparations, produced from plasma collected in Europe and the United States, confirmed highly potent neutralization of a seasonal coronavirus; however, no cross-neutralization of the new SARS-CoV-2 was seen.


Тема - темы
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , Immunoglobulins, Intravenous/immunology , SARS-CoV-2/immunology , COVID-19/virology , Cross Reactions , Europe , Humans , Neutralization Tests , Plasma/immunology , United States
Критерии поиска